{"product_id":"tech-eu-81-zpid-hg-holzvergaserkessel-steuerung","title":"TECH EU-81 zPID HG boiler control for wood gasification boilers","description":"\u003cp data-start=\"1140\" data-end=\"1395\"\u003eThe \u003cstrong data-start=\"1144\" data-end=\"1166\"\u003eTECH EU-81 zPID HG\u003c\/strong\u003e is a microprocessor-controlled boiler control unit with PID control, \u003cstrong data-start=\"1235\" data-end=\"1270\"\u003especifically for wood gasification boilers\u003c\/strong\u003e. It controls the fan, heating and hot water pump and optimizes the combustion process via an additional flue gas sensor.\u003c\/p\u003e\n\u003chr data-start=\"1397\" data-end=\"1400\"\u003e\n\u003ch2 data-start=\"1402\" data-end=\"1428\"\u003eHighlights \/ Benefits\u003c\/h2\u003e\n\u003cp data-start=\"1429\" data-end=\"1683\"\u003e⭐ Specifically designed for wood gasification boilers\u003cbr data-start=\"1472\" data-end=\"1475\"\u003e⭐ PID control with additional flue gas sensor\u003cbr data-start=\"1518\" data-end=\"1521\"\u003e⭐ Constant boiler temperature and stable operation\u003cbr data-start=\"1570\" data-end=\"1573\"\u003e⭐ Reduced emissions through optimized combustion\u003cbr data-start=\"1625\" data-end=\"1628\"\u003e⭐ Control of fan, heating and hot water pump\u003c\/p\u003e\n\u003chr data-start=\"1685\" data-end=\"1688\"\u003e\n\u003ch2 data-start=\"1690\" data-end=\"1718\"\u003eDetailed description\u003c\/h2\u003e\n\u003ch3 data-start=\"1720\" data-end=\"1753\"\u003eArea of application \u0026 target group\u003c\/h3\u003e\n\u003cp data-start=\"1754\" data-end=\"2008\"\u003eThe EU-81 zPID HG is \u003cstrong data-start=\"1776\" data-end=\"1833\"\u003eintended exclusively for operation on wood gasification boilers\u003c\/strong\u003e . It is suitable for heating systems in residential areas as well as for technical applications where precise temperature and combustion control is required.\u003c\/p\u003e\n\u003ch3 data-start=\"2010\" data-end=\"2034\"\u003eEveryday benefits\u003c\/h3\u003e\n\u003cp data-start=\"2035\" data-end=\"2298\"\u003eThanks to PID control with flue gas sensor, combustion is continuously monitored and adjusted. Temperature fluctuations are minimized, and the boiler operates more quietly and efficiently. This increases operating comfort and supports uniform heating operation.\u003c\/p\u003e\n\u003ch3 data-start=\"2300\" data-end=\"2327\"\u003eTechnology \u0026 equipment\u003c\/h3\u003e\n\u003cp data-start=\"2328\" data-end=\"2349\"\u003eThe control unit regulates:\u003c\/p\u003e\n\u003cul data-start=\"2350\" data-end=\"2431\"\u003e\n\u003cli data-start=\"2350\" data-end=\"2372\"\u003e\n\u003cp data-start=\"2352\" data-end=\"2372\"\u003ethe supply air (fan),\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2373\" data-end=\"2399\"\u003e\n\u003cp data-start=\"2375\" data-end=\"2399\"\u003ethe heating circulation pump,\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2400\" data-end=\"2431\"\u003e\n\u003cp data-start=\"2402\" data-end=\"2431\"\u003ethe hot water pump (boiler).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2433\" data-end=\"2616\"\u003eIn addition, a flue gas sensor permanently monitors the flue gas temperature. If the temperature rises, the fan output is automatically reduced or switched off to prevent overheating.\u003c\/p\u003e\n\u003ch3 data-start=\"2618\" data-end=\"2642\"\u003eEfficiency \u0026 environment\u003c\/h3\u003e\n\u003cp data-start=\"2643\" data-end=\"2884\"\u003eControlled combustion ensures uniform heat generation and can reduce fuel consumption. At the same time, emissions of dust particles and gases are reduced because the heat energy of the flue gases is better utilized.\u003c\/p\u003e\n\u003ch3 data-start=\"2886\" data-end=\"2926\"\u003eCompatibility \u0026 system integration\u003c\/h3\u003e\n\u003cp data-start=\"2927\" data-end=\"3170\"\u003eThe EU-81 zPID HG is designed for classic hydraulic heating systems with wood gasification boiler. Various operating modes such as heating mode, parallel pumps, summer mode or hot water priority allow flexible adaptation to the system.\u003c\/p\u003e\n\u003chr data-start=\"3172\" data-end=\"3175\"\u003e\n\u003ch2 data-start=\"3177\" data-end=\"3196\"\u003eTechnical data\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"3198\" data-end=\"3611\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"3198\" data-end=\"3216\"\u003e\n\u003ctr data-start=\"3198\" data-end=\"3216\"\u003e\n\u003cth data-start=\"3198\" data-end=\"3208\" data-col-size=\"sm\" class=\"\"\u003eFeature\u003c\/th\u003e\n\u003cth data-start=\"3208\" data-end=\"3216\" data-col-size=\"sm\" class=\"\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"3234\" data-end=\"3611\"\u003e\n\u003ctr data-start=\"3234\" data-end=\"3267\"\u003e\n\u003ctd data-start=\"3234\" data-end=\"3247\" data-col-size=\"sm\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd data-start=\"3247\" data-end=\"3267\" data-col-size=\"sm\"\u003eTECH Controllers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3268\" data-end=\"3294\"\u003e\n\u003ctd data-start=\"3268\" data-end=\"3277\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-start=\"3277\" data-end=\"3294\" data-col-size=\"sm\"\u003eEU-81 zPID HG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3295\" data-end=\"3327\"\u003e\n\u003ctd data-start=\"3295\" data-end=\"3308\" data-col-size=\"sm\"\u003eProduct type\u003c\/td\u003e\n\u003ctd data-start=\"3308\" data-end=\"3327\" data-col-size=\"sm\"\u003eBoiler control unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3328\" data-end=\"3369\"\u003e\n\u003ctd data-start=\"3328\" data-end=\"3346\" data-col-size=\"sm\"\u003ePower supply\u003c\/td\u003e\n\u003ctd data-start=\"3346\" data-end=\"3369\" data-col-size=\"sm\"\u003e230 V ±10% \/ 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3370\" data-end=\"3397\"\u003e\n\u003ctd data-start=\"3370\" data-end=\"3390\" data-col-size=\"sm\"\u003ePower consumption\u003c\/td\u003e\n\u003ctd data-start=\"3390\" data-end=\"3397\" data-col-size=\"sm\"\u003e5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3398\" data-end=\"3431\"\u003e\n\u003ctd data-start=\"3398\" data-end=\"3420\" data-col-size=\"sm\"\u003eAmbient temperature\u003c\/td\u003e\n\u003ctd data-start=\"3420\" data-end=\"3431\" data-col-size=\"sm\"\u003e5–50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3432\" data-end=\"3458\"\u003e\n\u003ctd data-start=\"3432\" data-end=\"3450\" data-col-size=\"sm\"\u003eMeasurement accuracy\u003c\/td\u003e\n\u003ctd data-start=\"3450\" data-end=\"3458\" data-col-size=\"sm\"\u003e1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3459\" data-end=\"3499\"\u003e\n\u003ctd data-start=\"3459\" data-end=\"3490\" data-col-size=\"sm\"\u003eMax. load fan output\u003c\/td\u003e\n\u003ctd data-start=\"3490\" data-end=\"3499\" data-col-size=\"sm\"\u003e0.6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3500\" data-end=\"3540\"\u003e\n\u003ctd data-start=\"3500\" data-end=\"3531\" data-col-size=\"sm\"\u003eMax. load pump output\u003c\/td\u003e\n\u003ctd data-start=\"3531\" data-end=\"3540\" data-col-size=\"sm\"\u003e0.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3541\" data-end=\"3588\"\u003e\n\u003ctd data-start=\"3541\" data-end=\"3570\" data-col-size=\"sm\"\u003eTemperature range sensors\u003c\/td\u003e\n\u003ctd data-start=\"3570\" data-end=\"3588\" data-col-size=\"sm\"\u003e−30 to +99 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3589\" data-end=\"3611\"\u003e\n\u003ctd data-start=\"3589\" data-end=\"3601\" data-col-size=\"sm\"\u003eFuse\u003c\/td\u003e\n\u003ctd data-start=\"3601\" data-end=\"3611\" data-col-size=\"sm\"\u003e3.15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"3613\" data-end=\"3616\"\u003e\n\u003ch2 data-start=\"3618\" data-end=\"3635\"\u003eScope of delivery\u003c\/h2\u003e\n\u003cul data-start=\"3636\" data-end=\"3770\"\u003e\n\u003cli data-start=\"3636\" data-end=\"3669\"\u003e\n\u003cp data-start=\"3638\" data-end=\"3669\"\u003eBoiler control unit EU-81 zPID HG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3670\" data-end=\"3699\"\u003e\n\u003cp data-start=\"3672\" data-end=\"3699\"\u003eTemperature sensor (boiler)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3700\" data-end=\"3725\"\u003e\n\u003cp data-start=\"3702\" data-end=\"3725\"\u003eFlue gas temperature sensor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3726\" data-end=\"3749\"\u003e\n\u003cp data-start=\"3728\" data-end=\"3749\"\u003eOperating instructions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3750\" data-end=\"3770\"\u003e\n\u003cp data-start=\"3752\" data-end=\"3770\"\u003eInstallation instructions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3772\" data-end=\"3775\"\u003e\n\u003ch2 data-start=\"3777\" data-end=\"3802\"\u003eAccessories \/ Recommendation\u003c\/h2\u003e\n\u003cul data-start=\"3803\" data-end=\"3967\"\u003e\n\u003cli data-start=\"3803\" data-end=\"3830\"\u003e\n\u003cp data-start=\"3805\" data-end=\"3830\"\u003eReplacement temperature sensor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3831\" data-end=\"3856\"\u003e\n\u003cp data-start=\"3833\" data-end=\"3856\"\u003eFlue gas temperature sensor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3857\" data-end=\"3895\"\u003e\n\u003cp data-start=\"3859\" data-end=\"3895\"\u003eConnection cables and mounting material\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3896\" data-end=\"3967\"\u003e\n\u003cp data-start=\"3898\" data-end=\"3967\"\u003eAdvanced control and safety technology for wood gasification boilers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3969\" data-end=\"4018\"\u003eYou can find suitable accessories at \u003cstrong data-start=\"4002\" data-end=\"4017\"\u003egemashop.de\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"4020\" data-end=\"4023\"\u003e\n\u003ch2 data-start=\"4025\" data-end=\"4060\"\u003eInstallation \u0026 safety instructions\u003c\/h2\u003e\n\u003cp data-start=\"4061\" data-end=\"4313\"\u003eInstallation and commissioning may \u003cstrong data-start=\"4102\" data-end=\"4143\"\u003eonly be carried out by qualified specialist personnel\u003c\/strong\u003e .\u003cbr data-start=\"4153\" data-end=\"4156\"\u003eThe control unit is \u003cstrong data-start=\"4174\" data-end=\"4215\"\u003eintended exclusively for wood gasification boilers\u003c\/strong\u003e .\u003cbr data-start=\"4227\" data-end=\"4230\"\u003eWork on the electrical system may only be carried out in a de-energized state.\u003c\/p\u003e\n\u003chr data-start=\"4315\" data-end=\"4318\"\u003e\n\u003ch2 data-start=\"4320\" data-end=\"4326\"\u003eFAQ\u003c\/h2\u003e\n\u003cp data-start=\"4328\" data-end=\"4422\"\u003e\u003cstrong data-start=\"4328\" data-end=\"4381\"\u003eWhich boilers is the EU-81 zPID HG suitable for?\u003c\/strong\u003e\u003cbr data-start=\"4381\" data-end=\"4384\"\u003eExclusively for wood gasification boilers.\u003c\/p\u003e\n\u003cp data-start=\"4424\" data-end=\"4587\"\u003e\u003cstrong data-start=\"4424\" data-end=\"4497\"\u003eHow does the HG variant differ from the standard EU-81 zPID?\u003c\/strong\u003e\u003cbr data-start=\"4497\" data-end=\"4500\"\u003eFunctionally identical, but clearly and exclusively intended for wood gasification boilers.\u003c\/p\u003e\n\u003cp data-start=\"4589\" data-end=\"4688\"\u003e\u003cstrong data-start=\"4589\" data-end=\"4628\"\u003eWhich components are controlled?\u003c\/strong\u003e\u003cbr data-start=\"4628\" data-end=\"4631\"\u003eCombustion air (fan), heating circulation pump, and domestic hot water pump.\u003c\/p\u003e\n\u003cp data-start=\"4690\" data-end=\"4821\"\u003e\u003cstrong data-start=\"4690\" data-end=\"4729\"\u003eWhat is the function of the flue gas sensor?\u003c\/strong\u003e\u003cbr data-start=\"4729\" data-end=\"4732\"\u003eIt monitors the flue gas temperature and optimizes combustion as well as fan control.\u003c\/p\u003e\n\u003cp data-start=\"4823\" data-end=\"4947\"\u003e\u003cstrong data-start=\"4823\" data-end=\"4861\"\u003eAre there different operating modes?\u003c\/strong\u003e\u003cbr data-start=\"4861\" data-end=\"4864\"\u003eYes, including heating mode, parallel pump operation, summer mode, and domestic hot water priority.\u003c\/p\u003e\n\u003cp data-start=\"4949\" data-end=\"5043\"\u003e\u003cstrong data-start=\"4949\" data-end=\"4986\"\u003eWho is allowed to install the controller?\u003c\/strong\u003e\u003cbr data-start=\"4986\" data-end=\"4989\"\u003eInstallation may only be carried out by a qualified specialist company.\u003c\/p\u003e\n\u003chr data-start=\"5045\" data-end=\"5048\"\u003e\n\u003ch2 data-start=\"5050\" data-end=\"5060\"\u003eConclusion\u003c\/h2\u003e\n\u003cp data-start=\"5061\" data-end=\"5282\"\u003eThe \u003cstrong data-start=\"5065\" data-end=\"5087\"\u003eTECH EU-81 zPID HG\u003c\/strong\u003e is a precise and reliable boiler controller for wood gasification boilers. It combines PID control with flue gas monitoring and offers safe, efficient control of modern wood heating systems.\u003c\/p\u003e","brand":"Tech","offers":[{"title":"Numatytasis pavadinimas","offer_id":47098276315484,"sku":"DE200HG","price":237.51,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/tech-eu-81-zpid-kesselsteuerung-pid-heizungsregler-mit-abgassensor-3873052.webp?v=1770693385","url":"https:\/\/lt.gemashop.de\/en\/products\/tech-eu-81-zpid-hg-medienvaldymo-irenginys-dujofikuojantiems-medienos-katilams","provider":"GEMA Shop","version":"1.0","type":"link"}