Product Overview & Application Area
The Sinclair KEYON SIH-24BIK + SOH-24BIK split air conditioner 6.2 kW with Wi-Fi is a powerful single-split wall-mounted unit set for cooling and heating operation. The set consists of the indoor unit SIH-24BIK and the outdoor unit SOH-24BIK and is intended for rooms where permanently installed air conditioning with a separate outdoor unit is desired.
With 6.2 kW cooling capacity and 6.5 kW heating capacity, the system is suitable for larger living and working areas, offices, practices, or smaller commercial spaces, provided that the specific design is professionally checked based on the room and building situation.
Technology & Equipment
The KEYON series is designed as a split wall-mounted unit: the indoor unit handles air distribution, room air treatment, and operating comfort in the room, while the outdoor unit forms the outdoor part of the refrigeration circuit. The system operates with the refrigerant R32 and is designed for cooling and heating operation.
The confirmed equipment includes Wi-Fi control, remote control YAA1FB6, I FEEL function, 8 °C tempering heating function, hidden display, horizontal air deflection, dehumidification operation, and cold plasma ionizer. According to the manufacturer, the indoor unit's air distribution reaches up to 1100 m³/h.
Everyday Benefits
The system can cool rooms in summer and, during the transitional period, can also be used as an air-to-air heat pump for heating. Operation is via remote control and Wi-Fi function, so temperature, operating mode, fan speed, and timer can be set conveniently.
The I FEEL function supports user-centric temperature control via the remote control's sensor. The dehumidification mode, X-FAN function, and automatic cleaning function support practical everyday operation without replacing regular filter care and maintenance.
System Integration & Compatibility
The product is classified as a single-split air conditioning set with indoor unit SIH-24BIK and outdoor unit SOH-24BIK. According to the technical specification, power is supplied via the outdoor unit at 220–240 V, 1 phase, and 50 Hz.
The refrigerant lines are specified as 1/4 inch or 6 mm for the liquid line and 1/2 inch or 12 mm for the gas line. The maximum pipe length is 25 m, and the maximum height difference is 10 m. The specific installation must be planned and carried out by qualified specialists.
Technical data at a glance
The following information refers to the specific air conditioning unit or the specifically offered air conditioning set.
| Product type | Single-split wall unit / split air conditioning system |
| Components | Indoor unit SIH-24BIK, outdoor unit SOH-24BIK |
| Cooling capacity | 6.2 kW, capacity range 1.8–6.4 kW |
| Heating output | 6.5 kW, output range 1.6–6.6 kW |
| SEER / SCOP | 6.8 / 4.0 |
| Energy efficiency class cooling / heating | A++ / A+ |
| Refrigerant | R32, GWP 675 |
| Dehumidification capacity | 1.8 l/h |
| Air flow rate | Indoor unit 1100 / 950 / 750 / 650 m³/h, outdoor unit 2800 m³/h |
| Sound pressure level | Indoor unit 48 / 44 / 40 / 35 dB(A), outdoor unit 58 dB(A) |
| Sound power level | Indoor unit 61 / 58 / 53 / 49 dB(A), outdoor unit 67 dB(A) |
| Power supply | 220–240 V / 1 Ph / 50 Hz, supply via outdoor unit |
| Power input cooling / heating | 1.77 / 1.65 kW |
| Power consumption cooling / heating | 7.9 / 7.3 A |
| Indoor unit dimensions | 1081 x 325 x 248 mm |
| Outdoor unit dimensions | 873 x 555 x 376 mm |
| Weight | Indoor unit 16.5 / 19.5 kg net / gross, outdoor unit 36.5 / 39.5 kg net / gross |
| Refrigerant lines | Liquid line 1/4 inch / 6 mm, gas line 1/2 inch / 12 mm |
| Pipe length / height difference | 3–25 m pipe length, max. 10 m height difference |
| Operating range cooling / heating | -15 to 43 °C / -15 to 24 °C |
Installation
The Sinclair KEYON SIH-24BIK + SOH-24BIK is a split air conditioning system with separate indoor and outdoor units. Installation location, pipe lengths, height difference, condensate drainage, electrical supply, and proper integration must be checked before installation.
Installation, electrical connection, refrigerant work, leak testing, evacuation, and commissioning may only be carried out by qualified specialists or a certified refrigeration contractor. The unit contains R32 and must not be opened or worked on in the refrigerant circuit by untrained persons.
Notes
For safe and reliable operation, free air paths at the indoor and outdoor units, regular filter maintenance, and compliance with the manufacturer's specifications are important. The air conditioning system must be switched off and disconnected from the power supply before cleaning.
The performance data serve for technical classification. The actual suitability for a room depends, among other things, on room size, insulation standard, window areas, orientation, internal heat loads, and desired temperature range, and does not replace proper cooling load or installation planning.
Scope of delivery
- Sinclair KEYON climate set SIH-24BIK + SOH-24BIK
- Indoor unit SIH-24BIK
- Outdoor unit SOH-24BIK
- Remote control YAA1FB6 (WiFi)
- WiFi control / WiFi module according to manufacturer's specification