{"product_id":"pufferspeicher-sunex-fish-s4-500-x-505-liter","title":"Sunex FISH S4 500 X buffer tank 505 liters","description":"\u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eProduct Overview \u0026amp; Application Area\u003c\/h2\u003e \u003cp\u003eThe Sunex FISH S4 500 X is a standing buffer tank with a storage capacity of 505 liters for heating systems with solid fuel boilers, oil or gas heating, heat pumps, or electric boilers. It serves to buffer system water and supports a more even hydraulic integration between the heat generator and the heating circuit.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eTechnology \u0026amp; Equipment\u003c\/h2\u003e \u003cp\u003eThe tank is designed as a buffer tank without an integrated heat exchanger. The vessel is made of S235JR, is automatically welded, and has a gray outer jacket. The hydraulic connections are designed as G 1 1\/2\u0026quot; female threads, and the sensor connections as G 1\/2\u0026quot; female threads.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eEveryday Benefits\u003c\/h2\u003e \u003cp\u003eWith a capacity of 505 liters, the tank is suitable for heating systems that require a larger buffer volume than compact small tanks. The connection arrangement allows flexible integration of the heat source, heating circuit, and temperature sensing. The 50 mm thick polyurethane foam insulation with PVC foil layer reduces heat losses and protects the tank in regular system operation.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eSystem Integration \u0026amp; Compatibility\u003c\/h2\u003e \u003cp\u003eThe Sunex FISH S4 500 X can be used in systems with solid fuel boilers, oil and gas heating, heat pumps, or electric boilers. Solar support in this tank series is not provided via an integrated heat exchanger but must be planned through suitable system hydraulics or an additional heat exchanger in the system. For use with chilled water from 7 to 12 °C, the connection stubs must additionally be insulated against condensation and heat absorption.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"product-th\"\u003e \u003cstyle\u003e .product-th{margin-top:2rem}.product-th h2{margin:0 0 1rem}.product-th__table{width:100%;border-collapse:separate;border-spacing:0}.product-th__table td{padding:.95rem 1rem;vertical-align:top}.product-th__label{font-weight:700;width:38%;color:#213670}.product-th__value{color:#1f2937}.product-th__table tr:nth-child(odd) td{background:#f4f7fb}.product-th__table tr:nth-child(even) td{background:#fafbfd} \u003c\/style\u003e \u003ch2\u003eTechnical Data at a Glance\u003c\/h2\u003e \u003ctable class=\"product-th__table\"\u003e \u003ctbody\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eSUNEX S.A.\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eModel\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eFISH S4 500 X\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eStorage type\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eBuffer tank without integrated heat exchanger\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eStorage volume\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e505 l\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eEnergy efficiency class\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eStandby heat loss\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e71 W\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eMax. operating temperature\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e95 °C\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eMax. operating pressure\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e3 bar\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eTest pressure\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e4.5 bar\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eInsulation\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e50 mm polyurethane foam with PVC foil layer\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eStorage tank material\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eS235JR\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eDiameter with insulation\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e757 mm\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eDiameter without insulation\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e650 mm\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eHeight \/ Diagonal\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e1782 \/ 1891 mm\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eHydraulic connections\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eG 1 1\/2\u0026quot; female thread\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eSensor connections\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eG 1\/2\u0026quot; female thread\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eVenting\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eG 1 1\/2\u0026quot; female thread\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e100 kg\u003c\/td\u003e\n\u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eInstallation\u003c\/h2\u003e \u003cp\u003eThe storage tank must be installed vertically on a level, load-bearing surface. Before installation, check the transport route, ceiling height, door widths, floor load, and connection side. All connections must be made without stress, unused connections must be properly sealed, and venting must be provided at the highest point of the system.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eNotes\u003c\/h2\u003e \u003cp\u003eThe storage tank is intended for heating or system water and is not described as a drinking water storage tank. Installation, connection, commissioning, and maintenance must be carried out by qualified personnel in accordance with applicable engineering standards. Operating pressure, temperature limits, and proper hydraulic planning must be observed.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eScope of delivery\u003c\/h2\u003e \u003cul\u003e \u003cli\u003eSunex FISH S4 500 X buffer tank 505 liters\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e","brand":"Sunex","offers":[{"title":"Numatytasis pavadinimas","offer_id":58156515033436,"sku":"SS4500","price":639.92,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/Sunex_Fish_S4.png?v=1782722048","url":"https:\/\/lt.gemashop.de\/en\/products\/pufferspeicher-sunex-fish-s4-500-x-505-liter","provider":"GEMA Shop","version":"1.0","type":"link"}