{"product_id":"gema-mdc-plus-400-bundle-modul-heizstab-eehppv9-9-0-kw-400-v","title":"GEMA MDC PLUS 400 heating module + heating rod EEHPPV9 9.0 kW 400 V","description":"\u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eProduct Overview \u0026amp; Area of Application\u003c\/h2\u003e \u003cp\u003eThe GEMA MDC PLUS 400 bundle module + heating rod EEHPPV9 9.0 kW 400 V combines an MDC PLUS 400 heating module with a matching electric heating cartridge for supplementary heat input into central heating systems.\u003c\/p\u003e \u003cp\u003eThe bundle is suitable for heating systems in which electric supplementary heat, supplementary heating, frost protection support, emergency heat support, or the use of surplus PV power as heat in the heating circuit is intended. Proper hydraulic and electrical integration remains crucial here.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eTechnology \u0026amp; Equipment\u003c\/h2\u003e \u003cp\u003eThe MDC PLUS 400 is an electric heating module, or rather an electric flow heater for central heating systems. It is integrated into the heating circuit and is designed for water or a suitable glycol mixture up to a maximum concentration of 50%.\u003c\/p\u003e \u003cp\u003eThe EEHPPV9 electric heating cartridge provides 9.0 kW of electric heating output at 3~ 400 V. The output can be set to 3 kW, 6 kW, or 9 kW via the separate 3-step rotary switch. Temperature control operates in the range of approx. 5 to 75 °C; a safety temperature limiter interrupts operation in the event of overheating.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eEveryday Benefits\u003c\/h2\u003e \u003cp\u003eThe bundle supports existing heating systems with a clearly defined electric supplementary heat source. This allows heat to be introduced into the heating circuit in a targeted manner when the main heat generator is to be supplemented or temporarily relieved.\u003c\/p\u003e \u003cp\u003eThe stepwise output selection of the heating cartridge is particularly helpful when the full rated output is not permanently required. Operators thus receive a more adaptable electric supplementary heating system for practical plant operation.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eSystem Integration \u0026amp; Compatibility\u003c\/h2\u003e \u003cp\u003eThe MDC PLUS 400 is integrated into a parallel heating circuit on the flow or return line of the main heat source. It is intended for use in open and closed central heating systems with appropriate safety devices.\u003c\/p\u003e \u003cp\u003eFor operation at 9.0 kW, a minimum flow rate of 514 l\/h is required. An additional circulation pump must be provided and connected in parallel to the heating cartridge. The safety valve, electrical protection, control connection, and necessary installation materials must be professionally checked on the system side.\u003c\/p\u003e \u003c\/div\u003e \u003cstyle\u003e .product-th{margin-top:2rem}.product-th h2{margin:0 0 1rem}.product-th__table{width:100%;border-collapse:separate;border-spacing:0}.product-th__table td{padding:.95rem 1rem;vertical-align:top}.product-th__label{font-weight:700;width:38%;color:#213670}.product-th__value{color:#1f2937}.product-th__table tr:nth-child(odd) td{background:#f4f7fb}.product-th__table tr:nth-child(even) td{background:#fafbfd} \u003c\/style\u003e \u003cdiv class=\"product-th\"\u003e \u003ch2\u003eTechnical data at a glance\u003c\/h2\u003e \u003cp\u003eThe following information refers to the specific bundle consisting of the MDC module and the matching electric heating cartridge.\u003c\/p\u003e \u003ctable class=\"product-th__table\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eBase module\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eMDC PLUS 400\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eHeating rod SKU\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eEEHPPV9\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eRated power\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e9.0 kW\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003ePower consumption\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e9,000 W\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eVoltage\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e3~ 400 V\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003ePhases\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e3\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eFrequency\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e~50 Hz\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eCurrent draw\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e13.0 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003ePower levels\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e3 \/ 6 \/ 9 kW via 3-stage rotary switch\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eTemperature control\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eapprox. 5 to 75 °C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eSafety temperature limiter\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eapprox. 93 °C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eInstallation length of heating cartridge\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e735 mm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eUnheated area\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e100 mm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eHeating cartridge connection size\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eG 1 1\/2 inch\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eModule connection heating circuit\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eFemale thread G 1 1\/4 inch\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eHeating cartridge connection module\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eFemale thread G 1 1\/2 inch\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eMedium\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eWater or suitable glycol mixture up to max. 50%\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eMinimum flow rate\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e514 l\/h, approx. 8.57 l\/min\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eMax. operating pressure\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e10 bar\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eMax. operating temperature module\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e90 °C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eDevice length module\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e850 mm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eInsulation\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e50 mm polyurethane foam\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eInstallation\u003c\/h2\u003e \u003cp\u003eThe heating module must be professionally integrated into the heating circuit. The pipe routing must ensure safe filling, venting, and flow through the system. An additional circulation pump is required for operation to maintain the necessary minimum flow rate.\u003c\/p\u003e \u003cp\u003eInstallation, electrical connection and commissioning may only be carried out by qualified specialists. Before switching on, the system and module must be completely filled and vented.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eNotes\u003c\/h2\u003e \u003cp\u003eDry running must be avoided, as this can damage the heating element. The heating cartridge may only be operated once the heating element is fully immersed in the medium and the minimum flow rate is ensured.\u003c\/p\u003e \u003cp\u003eThe device does not replace proper system planning, heat load calculation or electrical sizing. The safety valve, circulation pump, fuse protection, cable cross-section and control connection must be designed and checked to suit the system.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eScope of delivery\u003c\/h2\u003e \u003cul\u003e \u003cli\u003eMDC PLUS 400 heating module\u003c\/li\u003e \u003cli\u003eEEHPPV9 electric heating cartridge \/ EJK maxi 9000 MR with 9.0 kW\u003c\/li\u003e \u003cli\u003eFlat gasket or O-ring for the electric heating cartridge, insofar as it is part of the version in accordance with the heating cartridge documentation\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e","brand":"Gema GmbH","offers":[{"title":"Numatytasis pavadinimas","offer_id":58079685149020,"sku":"MDC400P+EEHPPV9","price":560.06,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/durchlauferhitzer-notheizung-mdc-400p-inkl-elektroheizstab-9-kw-4897799.webp?v=1770692302","url":"https:\/\/lt.gemashop.de\/en\/products\/gema-mdc-plus-400-bundle-module-heating-rod-eehppv9-9-0-kw-400-v","provider":"GEMA Shop","version":"1.0","type":"link"}